Description

Belmont Touch Phot-X IIS Intraoral X-Ray

Reliable with its No Drift Arm

Categories: Intraoral X-Ray, Intraoral X-Rays

  • The no drift arm on this ultra reliable unit from Belmont makes the Phot-X IIS intraoral x-ray an ideal unit for any surgery.
  • Easy to follow screen makes the Belmont Touch Intraoral X-ray the ideal unit for your surgery..
  • The sister unit to the Belmont Phot-X II Intraoral Unit

The Belmont Touch Phot X-IIS is Belmont's hugely popular intraoral X-ray. It has gained such a good reputation due to its clear, reliable imagery and ease of use.

This unit has gained a very strong reputation due to its ease of use, clear imagery and reliable performance, and the sister unit to Belmont's Phot-X Touch.

No Drift Arm

This wall-mounted unit as with all Belmont products is robust and ensures that the sissor arm has no drift, so when you place it in position, it stays there.

Easy to Use

The Phot-X II operates easily. Easily select the right exposure setting and type of patient, as well as the area of the mouth you wish to expose, with clear icons. Manual override functionality. With the control panel mounted outside the surgery.

Versatile

Compatible with all digital systems and film. It can switch between digital and film at the push of a button.

Robust

As with all the Belmont range, the Phot-X II x-ray is built with quality material and made to last and withstand the demands of a a busy practice.

Belmont is a Japanese manufacturer that has established itself in the industry as being one of the best, most reliable brands for a range of equipment including Dental Chairs and X-rays, with a strong UK base in London, with parts and engineers readily available should you require it.

Additional benefits of the Belmont Touch Phot-X II are:

Safety First

A safety-conscious X-Ray unit with exposures as low as 0.01 seconds. Over-exposure is easily avoided with a large range of exposure settings

Ease of Use

It's a user-friendly unit that is simple to operate:

  • It has adult, adolescent and child presets for the user or a manual overide for more challenging exposures.
  • With a Multilingual display for a range of users.
  • A USB for traceability.
  • The control panel mounted outside the surgery.

Mounting Options

Choose between wall-mounted, mobile base, unit with stool or ceiling mounted.

Arm Length

Choose between short, medium and long arm mounting.

Focal Spot

Recessed Focal spot allows for the shorter come and longer ‘Source to skin’ distance of 203mm

Easy to Clean

The x-rays screen and the simplicity of the unit make it easy to wipe down.

Experience the entire Belmont Dental Chair Range in the Brochure
Specifications for the Belmont Phot-X II Intraoral X-Ray are:
X-ray tube

Toshiba D-0711 (Stationary Anode)

Focal Spot

0.7 mm

Target Material

Tungsten

Target Angle

16 ̊

Maximum anode heat content

7kJ (10kHU)

Maximum x-ray tube assembly heat content

120kJ (170kHU)

Rated peak tube potential

60 kV / 70 kV selectable

Rated tube current

4 mA / 7 mA selectable

Maximum rated peak tube potential

70 kV

Elitrical Ratings
Rated Line Voltage

230 Vac

Minimum Line Voltage

207 Vac

Maximum Line Voltage

253 Vac

Rated Line Power

1.5 kVA

Rated Line Current at 70kV,7mA

6.6 Aac

Maximum Line Current at 70kV,7mA

7.3 Aac

Internal Resistance

1.02Ω max.

Range of Line Voltage Regulation

0 ~ 3 %

Power line frequency

50Hz,Single Phase

Exposure time

0.01 ~ 3.2 sec.

Inherent filtration

1.7 mm Al Equivalent

Added filtration

0.3 mm Al

Minimum filtration permanently in useful beam

2.0 mm Al Equivalent at 70 kV

Nominal electrical output of H.V. generator

0.49 kW at 70 kV, 7 mA

Regular Cone

Source to skin distance- 203 mm

Field Size- mm dia., circular 

Long cone (option)

Source to skin distance-  305 mm

Field size- 8 mm dia., circular 

Rectangular cone (option)

Source to skin- 203 mm

Field size- 36 x 47 mm, rectangular

Maximum symmetrical radiation field

60 mm dia. at distal end of cone

Leaking technique factor

70 kV / 0.14 mA

(0.14 mA is maximum rated continuous current for 7 mA with a duty cycle 1 : 50)

Duty cycle

1 : 50 (0.5 sec. exposure with 25 sec. interval)

Maximum deviation of tube potential, tube current and exposure time

Below 0.1 sec. setting- ±10 kV, ±2 mA, ±5 msec.

0.1 sec. setting & up- ±5 kV, ±1 mA, ±10 msec.

Peak tube potential

Average of peak tube potentials during one exposure

Tube current

Average of tube current during one exposure

exposure time

Time period during x-ray is emitted

Half value layer

1.5 mm Al over

Source to the base of cone distance

94 mm

Environmental condition for storage

-20 ~ 70 ̊C, 10 ~ 90%, 500 ~ 1060hPa

Environmental condition for operation

10 ~ 40 ̊C, 30 ~ 75%, 700 ~ 1060hPa

Movable range of head

Horizontal 0 ~ 600 ̊

Vertical 0 ~300

Site survey: Recommended

Practice Design Centre
Visit our extensive showroom, and speak to our refurbishment experts, about creating your ideal working space. Compare equipment (New and Used) and furniture from our world leading brands. Talk interior design and let us help inspire you. Appointments include weekends and evenings.

Equipment Consultation
Talk to the team about a demonstration at your practice for this product. Working alongside the UK dental industry's best manufacturers we will provide honest independent adivce. Equipment trials available on some items.

Hague Dental Team understand the financial demands on any practice. The extensive funds required for any surgery refurbishment, or investment required on the development of a new squat practice. We work alongside leading finance brokers that support the dental industry, to ensure we can quickly and easily help you with finance options. Speak to us about this in more detail.